← Back to RadarPre-Survey County Walk-Around Packet (6 Separate 8.5" × 11" Letter Sheets)
Page 1 of 6 · Cover & Assignment Sheet 8.5" × 11" US Letter · 3-Hole-Punch Ready

Pre-Survey County Inspector Walk-Around Packet

Facility: Avir at Cotulla Location: Cotulla, TX (La Salle County) Last Survey: 2026-01-08 (10 mos ago)
How to Use Hand 1 Sheet to Each Department Lead

State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in La Salle (TX) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.

Today's 5 Sheets Top Tags Cited Nearby
Sheet Tag & Care Area Nearby Activity Hand Sheet To Result
Page 2 F0880 — Infection Prevention and Control 2 local write-ups DON / Unit Nurse [   ] Pass   [   ] Fix
Page 3 K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing 1 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 4 K0741 — Survey Compliance Standard (K0741) 1 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 5 K0712 — Quarterly Fire Drills Conducted Across All Three Shifts 1 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 6 K0355 — Survey Compliance Standard (K0355) 1 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Administrator Sign-Off: ___________________ DON Sign-Off: ___________________ Date: __________
Page 2 of 6 · Walk-Around Clipboard 1 of 5 8.5" × 11" US Letter · Assign to DON / Unit Nurse

F0880 (F-880): Infection Prevention and Control

Facility: Avir at Cotulla Local Hotspot: #1 (2 nearby citations) Checklist: CMS-20054
Step 1 Walk the Unit & Check These 4 Items (5 Minutes)
1. Do staff perform hand hygiene and change gloves between dirty and clean tasks during wound or incontinence care? [   ] Pass   [   ] Fix Fix note:
2. Is Enhanced Barrier Precautions (EBP) or Transmission-Based Precautions signage posted on the door with stocked PPE caddy? [   ] Pass   [   ] Fix Fix note:
3. Are glucometers and shared vital-sign equipment disinfected with EPA-registered wipes observing exact wet-contact time? [   ] Pass   [   ] Fix Fix note:
4. Is clean linen kept covered and separated from soiled utility bags in hallways? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. What is the wet-contact kill time printed on our facility's disinfectant wipes before a shared glucometer can be reused? [   ] Answered Clearly   [   ] Coached
Q2. When caring for a resident on Enhanced Barrier Precautions with an indwelling catheter or wound, when must you wear gown and gloves? [   ] Answered Clearly   [   ] Coached
Q3. During peri-care or dressing changes, at what exact point must you remove dirty gloves and sanitize your hands? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 3 of 6 · Walk-Around Clipboard 2 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0918 (K-918): Electrical Systems - Essential Electric System Maintenance and Generator Testing

Facility: Avir at Cotulla Local Hotspot: #2 (1 nearby citations) Checklist: LSC-K0918
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? [   ] Pass   [   ] Fix Fix note:
2. Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? [   ] Pass   [   ] Fix Fix note:
3. Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? [   ] Answered Clearly   [   ] Coached
Q2. Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? [   ] Answered Clearly   [   ] Coached
Q3. Within how many seconds must emergency generator power come on if utility power fails? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 4 of 6 · Walk-Around Clipboard 3 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0741 (K-741): Survey Compliance Standard (K0741)

Facility: Avir at Cotulla Local Hotspot: #3 (1 nearby citations) Checklist: LSC
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are physical building zones and equipment covered by K0741 inspected and current in the maintenance log? [   ] Pass   [   ] Fix Fix note:
2. Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? [   ] Pass   [   ] Fix Fix note:
3. Were any open maintenance work orders resolved and dated by plant operations staff? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Where are weekly and monthly inspection records for K-741 stored? [   ] Answered Clearly   [   ] Coached
Q2. How do staff submit an urgent maintenance work order if equipment needs repair on shift? [   ] Answered Clearly   [   ] Coached
Q3. What safety step happens on your unit when the fire alarm activates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 5 of 6 · Walk-Around Clipboard 4 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0712 (K-712): Quarterly Fire Drills Conducted Across All Three Shifts

Facility: Avir at Cotulla Local Hotspot: #4 (1 nearby citations) Checklist: LSC-K0712
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Were unannounced fire drills completed at varied times at least once per quarter on Day, Evening, and Night shifts? [   ] Pass   [   ] Fix Fix note:
2. Do fire drill critique logs record alarm activation time, door closure, staff attendance, and corrective coaching? [   ] Pass   [   ] Fix Fix note:
3. Were silent night-shift drills between 9 PM and 6 AM followed by audible testing during daytime hours? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. What do the four letters in RACE stand for when responding to smoke or fire on your nursing unit? [   ] Answered Clearly   [   ] Coached
Q2. During a fire alarm, which residents near the fire origin are moved first beyond the smoke-barrier doors? [   ] Answered Clearly   [   ] Coached
Q3. Where are the last 12 quarterly shift fire drill logs filed when a Life Safety surveyor asks to see them? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 6 of 6 · Walk-Around Clipboard 5 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0355 (K-355): Survey Compliance Standard (K0355)

Facility: Avir at Cotulla Local Hotspot: #5 (1 nearby citations) Checklist: LSC
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are physical building zones and equipment covered by K0355 inspected and current in the maintenance log? [   ] Pass   [   ] Fix Fix note:
2. Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? [   ] Pass   [   ] Fix Fix note:
3. Were any open maintenance work orders resolved and dated by plant operations staff? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Where are weekly and monthly inspection records for K-355 stored? [   ] Answered Clearly   [   ] Coached
Q2. How do staff submit an urgent maintenance work order if equipment needs repair on shift? [   ] Answered Clearly   [   ] Coached
Q3. What safety step happens on your unit when the fire alarm activates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.