State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Goliad (TX) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 3 | K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 4 | F0880 — Infection Prevention and Control | 1 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 5 | F0759 — Medication Error Rates Below 5 Percent | 1 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 6 | F0690 — Bowel and Bladder Continence and Indwelling Catheter Care | 1 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? | [ ] Answered Clearly [ ] Coached |
| Q3. | When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |
| 1. | Do staff perform hand hygiene and change gloves between dirty and clean tasks during wound or incontinence care? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Is Enhanced Barrier Precautions (EBP) or Transmission-Based Precautions signage posted on the door with stocked PPE caddy? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are glucometers and shared vital-sign equipment disinfected with EPA-registered wipes observing exact wet-contact time? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Is clean linen kept covered and separated from soiled utility bags in hallways? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the wet-contact kill time printed on our facility's disinfectant wipes before a shared glucometer can be reused? | [ ] Answered Clearly [ ] Coached |
| Q2. | When caring for a resident on Enhanced Barrier Precautions with an indwelling catheter or wound, when must you wear gown and gloves? | [ ] Answered Clearly [ ] Coached |
| Q3. | During peri-care or dressing changes, at what exact point must you remove dirty gloves and sanitize your hands? | [ ] Answered Clearly [ ] Coached |
| 1. | Do active resident care plans and physician orders match floor practice observed under F0759? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Can nursing and CNA staff demonstrate policy steps during shift rounds without missing items? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were recent audit discrepancies corrected on the spot and reported to monthly QAPI? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What shift check do nursing staff complete to prevent citations under F-759? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where on the resident care plan or MAR do you verify current orders before care? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who do you notify right away if supplies, orders, or equipment are missing? | [ ] Answered Clearly [ ] Coached |
| 1. | Does every resident with an indwelling urinary catheter have a valid clinical indication and active physician order? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are catheter tubing straps secured to the thigh and drainage bags kept off the floor below bladder level? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are scheduled toileting plans and catheter care per shift documented accurately by nursing and CNA staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where should an indwelling catheter bag hang on the bed frame, and why must it stay below bladder level? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff secure catheter tubing to prevent pulling during resident transfers and peri-care? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where on the care plan do CNAs verify whether a resident is on a 2-hour scheduled toileting program? | [ ] Answered Clearly [ ] Coached |