State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Centre (PA) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | F0812 — Food Procurement, Store, Prepare, and Serve Sanitary | 9 local write-ups | Dietary Manager | [ ] Pass [ ] Fix |
| Page 3 | F0684 — Quality of Care (Non-Pressure Skin, Assessments, and Physician Orders) | 6 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 4 | K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors | 5 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 5 | K0363 — Corridor Doors Positive Latching and Free of Propping Wedges | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | F0947 — Survey Compliance Standard (F0947) | 4 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| 1. | Are all opened dry goods, walk-in cooler items, and freezer items tightly sealed, labeled, and dated with use-by dates? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are dishmachine wash/rinse temperatures or three-compartment sanitizer test strips logged before every meal service? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are dietary staff wearing hair restraints, clean aprons, and changing gloves appropriately? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are food holding temperatures logged and kept >= 135 F for hot foods and <= 41 F for cold foods until served? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the required sanitizer concentration (ppm) for our three-compartment sink test strips, and when is it logged? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you find an undated or expired item inside the nourishment fridge or walk-in cooler, what do you do immediately? | [ ] Answered Clearly [ ] Coached |
| Q3. | What minimum temperature must hot food maintain on the steam table before tray delivery starts? | [ ] Answered Clearly [ ] Coached |
| 1. | Are acute changes in resident condition assessed promptly by a licensed nurse and communicated to the physician and representative? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are non-pressure wounds (surgical incisions, skin tears, diabetic ulcers) treated strictly according to physician orders? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are ordered weights, vital signs, and neurological checks completed and documented without missed shifts? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | When a wound nurse practitioner visits and recommends a new dressing, what step must happen before the next treatment pass? | [ ] Answered Clearly [ ] Coached |
| Q2. | If a resident exhibits a sudden change in alertness, breathing, or skin integrity, what four actions must be documented? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where do you check whether a resident is currently on 72-hour post-fall neurological checks? | [ ] Answered Clearly [ ] Coached |
| 1. | Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? | [ ] Answered Clearly [ ] Coached |
| Q3. | When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0363 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-363 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Do active resident care plans and physician orders match floor practice observed under F0947? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Can nursing and CNA staff demonstrate policy steps during shift rounds without missing items? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were recent audit discrepancies corrected on the spot and reported to monthly QAPI? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What shift check do nursing staff complete to prevent citations under F-947? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where on the resident care plan or MAR do you verify current orders before care? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who do you notify right away if supplies, orders, or equipment are missing? | [ ] Answered Clearly [ ] Coached |