State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Choctaw (OK) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | F0656 — Develop and Implement Person-Centered Care Plans | 2 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 3 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 4 | K0912 — Survey Compliance Standard (K0912) | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 5 | K0344 — Survey Compliance Standard (K0344) | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| 1. | Does every active clinical device, fall safety intervention, catheter, or treatment order appear on the resident care plan and CNA Kardex? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Were care plans completed within 7 days of the admission MDS review by nursing and interdisciplinary staff? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Do bedside CNA care routines observed in resident rooms match the written care plan and physician orders? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where on your unit do nursing staff check a resident care plan for transfer level, diet texture, and fall mat safety before shift care? | [ ] Answered Clearly [ ] Coached |
| Q2. | When a resident gets new oxygen orders or a catheter today, which nurse updates the care plan and Kardex? | [ ] Answered Clearly [ ] Coached |
| Q3. | If a resident declines a care-planned heel boot during shift care, which nurse do you notify? | [ ] Answered Clearly [ ] Coached |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0912 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-912 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0344 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-344 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? | [ ] Answered Clearly [ ] Coached |
| Q3. | When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |