State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in La Moure (ND) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | F0880 — Infection Prevention and Control | 2 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 3 | F0761 — Labeling and Storage of Drugs and Biologicals | 2 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 4 | K0921 — Survey Compliance Standard (K0921) | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 5 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | K0914 — Survey Compliance Standard (K0914) | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| 1. | Do staff perform hand hygiene and change gloves between dirty and clean tasks during wound or incontinence care? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Is Enhanced Barrier Precautions (EBP) or Transmission-Based Precautions signage posted on the door with stocked PPE caddy? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are glucometers and shared vital-sign equipment disinfected with EPA-registered wipes observing exact wet-contact time? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Is clean linen kept covered and separated from soiled utility bags in hallways? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the wet-contact kill time printed on our facility's disinfectant wipes before a shared glucometer can be reused? | [ ] Answered Clearly [ ] Coached |
| Q2. | When caring for a resident on Enhanced Barrier Precautions with an indwelling catheter or wound, when must you wear gown and gloves? | [ ] Answered Clearly [ ] Coached |
| Q3. | During peri-care or dressing changes, at what exact point must you remove dirty gloves and sanitize your hands? | [ ] Answered Clearly [ ] Coached |
| 1. | Are all medication carts and treatment carts locked whenever out of the nurse's direct line of sight? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are multi-dose vials (such as insulin and tuberculin) labeled with open date and 28-day expiration date? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are Schedule II controlled substances stored inside separately locked, permanently affixed compartments? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are discontinued, expired, or discharged residents' medications promptly removed to the locked pharmacy-return bin? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | If you step into a resident's room or walk down the hall, what must you do with your medication or treatment cart first? | [ ] Answered Clearly [ ] Coached |
| Q2. | Once you puncture a multi-dose insulin vial, what date goes on the label and when does it expire? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where do discontinued blister packs go at the end of a med pass, and where is that return bin kept? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0921 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-921 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0914 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-914 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |