← Back to RadarPre-Survey County Walk-Around Packet (6 Separate 8.5" × 11" Letter Sheets)
Page 1 of 6 · Cover & Assignment Sheet 8.5" × 11" US Letter · 3-Hole-Punch Ready

Pre-Survey County Inspector Walk-Around Packet

Facility: Croasdaile Village Location: Durham, NC (Durham County) Last Survey: 2025-08-14 (15 mos ago)
How to Use Hand 1 Sheet to Each Department Lead

State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Durham (NC) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.

Today's 5 Sheets Top Tags Cited Nearby
Sheet Tag & Care Area Nearby Activity Hand Sheet To Result
Page 2 K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors 9 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 3 K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing 8 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 4 F0761 — Labeling and Storage of Drugs and Biologicals 7 local write-ups DON / Unit Nurse [   ] Pass   [   ] Fix
Page 5 K0521 — Survey Compliance Standard (K0521) 6 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 6 F0812 — Food Procurement, Store, Prepare, and Serve Sanitary 6 local write-ups Dietary Manager [   ] Pass   [   ] Fix
Administrator Sign-Off: ___________________ DON Sign-Off: ___________________ Date: __________
Page 2 of 6 · Walk-Around Clipboard 1 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0321 (K-321): Hazardous Areas - Enclosure and Self-Closing Smoke Doors

Facility: Croasdaile Village Local Hotspot: #1 (9 nearby citations) Checklist: LSC-K0321
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? [   ] Pass   [   ] Fix Fix note:
2. Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? [   ] Pass   [   ] Fix Fix note:
3. Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? [   ] Answered Clearly   [   ] Coached
Q2. If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? [   ] Answered Clearly   [   ] Coached
Q3. When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 3 of 6 · Walk-Around Clipboard 2 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0918 (K-918): Electrical Systems - Essential Electric System Maintenance and Generator Testing

Facility: Croasdaile Village Local Hotspot: #2 (8 nearby citations) Checklist: LSC-K0918
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? [   ] Pass   [   ] Fix Fix note:
2. Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? [   ] Pass   [   ] Fix Fix note:
3. Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? [   ] Answered Clearly   [   ] Coached
Q2. Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? [   ] Answered Clearly   [   ] Coached
Q3. Within how many seconds must emergency generator power come on if utility power fails? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 4 of 6 · Walk-Around Clipboard 3 of 5 8.5" × 11" US Letter · Assign to DON / Unit Nurse

F0761 (F-761): Labeling and Storage of Drugs and Biologicals

Facility: Croasdaile Village Local Hotspot: #3 (7 nearby citations) Checklist: CMS-20066
Step 1 Walk the Unit & Check These 4 Items (5 Minutes)
1. Are all medication carts and treatment carts locked whenever out of the nurse's direct line of sight? [   ] Pass   [   ] Fix Fix note:
2. Are multi-dose vials (such as insulin and tuberculin) labeled with open date and 28-day expiration date? [   ] Pass   [   ] Fix Fix note:
3. Are Schedule II controlled substances stored inside separately locked, permanently affixed compartments? [   ] Pass   [   ] Fix Fix note:
4. Are discontinued, expired, or discharged residents' medications promptly removed to the locked pharmacy-return bin? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. If you step into a resident's room or walk down the hall, what must you do with your medication or treatment cart first? [   ] Answered Clearly   [   ] Coached
Q2. Once you puncture a multi-dose insulin vial, what date goes on the label and when does it expire? [   ] Answered Clearly   [   ] Coached
Q3. Where do discontinued blister packs go at the end of a med pass, and where is that return bin kept? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 5 of 6 · Walk-Around Clipboard 4 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0521 (K-521): Survey Compliance Standard (K0521)

Facility: Croasdaile Village Local Hotspot: #4 (6 nearby citations) Checklist: LSC
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are physical building zones and equipment covered by K0521 inspected and current in the maintenance log? [   ] Pass   [   ] Fix Fix note:
2. Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? [   ] Pass   [   ] Fix Fix note:
3. Were any open maintenance work orders resolved and dated by plant operations staff? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Where are weekly and monthly inspection records for K-521 stored? [   ] Answered Clearly   [   ] Coached
Q2. How do staff submit an urgent maintenance work order if equipment needs repair on shift? [   ] Answered Clearly   [   ] Coached
Q3. What safety step happens on your unit when the fire alarm activates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 6 of 6 · Walk-Around Clipboard 5 of 5 8.5" × 11" US Letter · Assign to Dietary Manager

F0812 (F-812): Food Procurement, Store, Prepare, and Serve Sanitary

Facility: Croasdaile Village Local Hotspot: #5 (6 nearby citations) Checklist: CMS-20055
Step 1 Walk the Unit & Check These 4 Items (5 Minutes)
1. Are all opened dry goods, walk-in cooler items, and freezer items tightly sealed, labeled, and dated with use-by dates? [   ] Pass   [   ] Fix Fix note:
2. Are dishmachine wash/rinse temperatures or three-compartment sanitizer test strips logged before every meal service? [   ] Pass   [   ] Fix Fix note:
3. Are dietary staff wearing hair restraints, clean aprons, and changing gloves appropriately? [   ] Pass   [   ] Fix Fix note:
4. Are food holding temperatures logged and kept >= 135 F for hot foods and <= 41 F for cold foods until served? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. What is the required sanitizer concentration (ppm) for our three-compartment sink test strips, and when is it logged? [   ] Answered Clearly   [   ] Coached
Q2. If you find an undated or expired item inside the nourishment fridge or walk-in cooler, what do you do immediately? [   ] Answered Clearly   [   ] Coached
Q3. What minimum temperature must hot food maintain on the steam table before tray delivery starts? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.