State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Forsyth (NC) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | F0689 — Free of Accident Hazards, Supervision, and Assistance Devices | 7 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 3 | F0761 — Labeling and Storage of Drugs and Biologicals | 6 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 4 | F0760 — Residents Free of Significant Medication Errors | 6 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 5 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 5 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors | 5 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| 1. | Do transfer methods and mechanical lift sling sizes used by CNAs match the resident's active care plan and Kardex? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Were new fall-prevention interventions put in place immediately after the resident's most recent fall? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are call lights within reach, floor mats positioned as ordered, and bed heights set appropriately? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are smoking aprons, oxygen safety signs, and elopement wander-guards functioning and checked per shift? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Before transferring a resident with a mechanical lift, where do you check how many staff and which sling size are required? | [ ] Answered Clearly [ ] Coached |
| Q2. | When a resident has an unwitnessed fall, what immediate checks and care-plan updates happen before end of shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | Before walking out of a high-fall-risk resident's room, what three bedside items do you verify? | [ ] Answered Clearly [ ] Coached |
| 1. | Are all medication carts and treatment carts locked whenever out of the nurse's direct line of sight? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are multi-dose vials (such as insulin and tuberculin) labeled with open date and 28-day expiration date? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are Schedule II controlled substances stored inside separately locked, permanently affixed compartments? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are discontinued, expired, or discharged residents' medications promptly removed to the locked pharmacy-return bin? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | If you step into a resident's room or walk down the hall, what must you do with your medication or treatment cart first? | [ ] Answered Clearly [ ] Coached |
| Q2. | Once you puncture a multi-dose insulin vial, what date goes on the label and when does it expire? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where do discontinued blister packs go at the end of a med pass, and where is that return bin kept? | [ ] Answered Clearly [ ] Coached |
| 1. | Do active resident care plans and physician orders match floor practice observed under F0760? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Can nursing and CNA staff demonstrate policy steps during shift rounds without missing items? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were recent audit discrepancies corrected on the spot and reported to monthly QAPI? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What shift check do nursing staff complete to prevent citations under F-760? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where on the resident care plan or MAR do you verify current orders before care? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who do you notify right away if supplies, orders, or equipment are missing? | [ ] Answered Clearly [ ] Coached |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? | [ ] Answered Clearly [ ] Coached |
| Q3. | When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |