State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Stanly (NC) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 3 | K0511 — Utilities, HVAC, and Medical Gas Equipment Compliance | 3 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 4 | F0695 — Respiratory Care, Oxygen Therapy, Nebulizers, and Tracheostomy Care | 3 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 5 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 2 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | K0353 — Sprinkler System - Maintenance, Inspection, and 18-Inch Storage Clearance | 2 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| 1. | Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? | [ ] Answered Clearly [ ] Coached |
| Q3. | When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0511 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-511 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Does the oxygen concentrator liter flow set in the resident room match active physician orders on the MAR? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are nasal cannula tubing, humidifier bottles, and nebulizer treatment masks dated by nursing staff and stored in clean bags? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Is oxygen safety signage posted at the door and cylinders secured upright per facility policy? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Before starting oxygen or a nebulizer treatment for a resident, where do nursing staff verify physician orders? | [ ] Answered Clearly [ ] Coached |
| Q2. | On which night of the week do nursing staff change and date oxygen tubing on our unit? | [ ] Answered Clearly [ ] Coached |
| Q3. | How must a resident nebulizer mask be stored between treatments so it stays sanitary? | [ ] Answered Clearly [ ] Coached |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Do staff maintain at least 18 inches of vertical safety clearance below sprinkler heads in dietary, linen, and supply closets? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are sprinkler heads in resident rooms and corridors clean and free of paint, lint, or hanging items during maintenance inspection? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are quarterly flow tests and annual sprinkler inspection logs current in the facility maintenance binder? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | How many inches of open safety space must staff keep below sprinkler heads on top shelves of storage closets? | [ ] Answered Clearly [ ] Coached |
| Q2. | Can staff ever hang privacy curtains, clothes, or wires from sprinkler piping in a resident room? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where does the maintenance director keep quarterly and annual sprinkler inspection records? | [ ] Answered Clearly [ ] Coached |