State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Rosebud (MT) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 3 | F0883 — Influenza and Pneumococcal Resident Immunization | 1 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 4 | F0868 — Survey Compliance Standard (F0868) | 1 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 5 | F0812 — Food Procurement, Store, Prepare, and Serve Sanitary | 1 local write-ups | Dietary Manager | [ ] Pass [ ] Fix |
| Page 6 | F0880 — Infection Prevention and Control | 62 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Do active resident care plans and physician orders match floor practice observed under F0883? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Can nursing and CNA staff demonstrate policy steps during shift rounds without missing items? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were recent audit discrepancies corrected on the spot and reported to monthly QAPI? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What shift check do nursing staff complete to prevent citations under F-883? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where on the resident care plan or MAR do you verify current orders before care? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who do you notify right away if supplies, orders, or equipment are missing? | [ ] Answered Clearly [ ] Coached |
| 1. | Do active resident care plans and physician orders match floor practice observed under F0868? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Can nursing and CNA staff demonstrate policy steps during shift rounds without missing items? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were recent audit discrepancies corrected on the spot and reported to monthly QAPI? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What shift check do nursing staff complete to prevent citations under F-868? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where on the resident care plan or MAR do you verify current orders before care? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who do you notify right away if supplies, orders, or equipment are missing? | [ ] Answered Clearly [ ] Coached |
| 1. | Are all opened dry goods, walk-in cooler items, and freezer items tightly sealed, labeled, and dated with use-by dates? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are dishmachine wash/rinse temperatures or three-compartment sanitizer test strips logged before every meal service? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are dietary staff wearing hair restraints, clean aprons, and changing gloves appropriately? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are food holding temperatures logged and kept >= 135 F for hot foods and <= 41 F for cold foods until served? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the required sanitizer concentration (ppm) for our three-compartment sink test strips, and when is it logged? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you find an undated or expired item inside the nourishment fridge or walk-in cooler, what do you do immediately? | [ ] Answered Clearly [ ] Coached |
| Q3. | What minimum temperature must hot food maintain on the steam table before tray delivery starts? | [ ] Answered Clearly [ ] Coached |
| 1. | Do staff perform hand hygiene and change gloves between dirty and clean tasks during wound or incontinence care? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Is Enhanced Barrier Precautions (EBP) or Transmission-Based Precautions signage posted on the door with stocked PPE caddy? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are glucometers and shared vital-sign equipment disinfected with EPA-registered wipes observing exact wet-contact time? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Is clean linen kept covered and separated from soiled utility bags in hallways? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the wet-contact kill time printed on our facility's disinfectant wipes before a shared glucometer can be reused? | [ ] Answered Clearly [ ] Coached |
| Q2. | When caring for a resident on Enhanced Barrier Precautions with an indwelling catheter or wound, when must you wear gown and gloves? | [ ] Answered Clearly [ ] Coached |
| Q3. | During peri-care or dressing changes, at what exact point must you remove dirty gloves and sanitize your hands? | [ ] Answered Clearly [ ] Coached |