← Back to RadarPre-Survey County Walk-Around Packet (6 Separate 8.5" × 11" Letter Sheets)
Page 1 of 6 · Cover & Assignment Sheet 8.5" × 11" US Letter · 3-Hole-Punch Ready

Pre-Survey County Inspector Walk-Around Packet

Facility: Chesapeake Shores Nursing Center Location: Lexington Park, MD (St. Marys County) Last Survey: 2026-01-09 (10 mos ago)
How to Use Hand 1 Sheet to Each Department Lead

State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in St. Marys (MD) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.

Today's 5 Sheets Top Tags Cited Nearby
Sheet Tag & Care Area Nearby Activity Hand Sheet To Result
Page 2 K0353 — Sprinkler System - Maintenance, Inspection, and 18-Inch Storage Clearance 3 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 3 K0920 — Power Strips, Extension Cords, and Electrical Equipment Safety 2 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 4 K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing 2 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 5 K0345 — Fire Alarm System Testing, Inspection, and Out-of-Service Fire Watch 2 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 6 K0223 — Survey Compliance Standard (K0223) 2 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Administrator Sign-Off: ___________________ DON Sign-Off: ___________________ Date: __________
Page 2 of 6 · Walk-Around Clipboard 1 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0353 (K-353): Sprinkler System - Maintenance, Inspection, and 18-Inch Storage Clearance

Facility: Chesapeake Shores Nursing Center Local Hotspot: #1 (3 nearby citations) Checklist: LSC-K0353
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Do staff maintain at least 18 inches of vertical safety clearance below sprinkler heads in dietary, linen, and supply closets? [   ] Pass   [   ] Fix Fix note:
2. Are sprinkler heads in resident rooms and corridors clean and free of paint, lint, or hanging items during maintenance inspection? [   ] Pass   [   ] Fix Fix note:
3. Are quarterly flow tests and annual sprinkler inspection logs current in the facility maintenance binder? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. How many inches of open safety space must staff keep below sprinkler heads on top shelves of storage closets? [   ] Answered Clearly   [   ] Coached
Q2. Can staff ever hang privacy curtains, clothes, or wires from sprinkler piping in a resident room? [   ] Answered Clearly   [   ] Coached
Q3. Where does the maintenance director keep quarterly and annual sprinkler inspection records? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 3 of 6 · Walk-Around Clipboard 2 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0920 (K-920): Power Strips, Extension Cords, and Electrical Equipment Safety

Facility: Chesapeake Shores Nursing Center Local Hotspot: #2 (2 nearby citations) Checklist: LSC
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are physical building zones and equipment covered by K0920 inspected and current in the maintenance log? [   ] Pass   [   ] Fix Fix note:
2. Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? [   ] Pass   [   ] Fix Fix note:
3. Were any open maintenance work orders resolved and dated by plant operations staff? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Where are weekly and monthly inspection records for K-920 stored? [   ] Answered Clearly   [   ] Coached
Q2. How do staff submit an urgent maintenance work order if equipment needs repair on shift? [   ] Answered Clearly   [   ] Coached
Q3. What safety step happens on your unit when the fire alarm activates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 4 of 6 · Walk-Around Clipboard 3 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0918 (K-918): Electrical Systems - Essential Electric System Maintenance and Generator Testing

Facility: Chesapeake Shores Nursing Center Local Hotspot: #3 (2 nearby citations) Checklist: LSC-K0918
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? [   ] Pass   [   ] Fix Fix note:
2. Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? [   ] Pass   [   ] Fix Fix note:
3. Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? [   ] Answered Clearly   [   ] Coached
Q2. Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? [   ] Answered Clearly   [   ] Coached
Q3. Within how many seconds must emergency generator power come on if utility power fails? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 5 of 6 · Walk-Around Clipboard 4 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0345 (K-345): Fire Alarm System Testing, Inspection, and Out-of-Service Fire Watch

Facility: Chesapeake Shores Nursing Center Local Hotspot: #4 (2 nearby citations) Checklist: LSC-K0345
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are semi-annual smoke detector sensitivity checks and annual fire alarm vendor inspection reports complete in the binder? [   ] Pass   [   ] Fix Fix note:
2. Is the main fire alarm panel clear of unaddressed trouble signals during maintenance shift rounds? [   ] Pass   [   ] Fix Fix note:
3. Do staff know the written Fire Watch log procedure if the fire alarm system goes offline for more than 4 hours? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. If you hear a yellow trouble beep on the main fire alarm panel at the nurses' station, who do you call right away? [   ] Answered Clearly   [   ] Coached
Q2. Where is our facility Fire Watch clipboard kept if the alarm system is temporarily offline for maintenance? [   ] Answered Clearly   [   ] Coached
Q3. Where does the maintenance director file quarterly and annual fire alarm testing certificates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 6 of 6 · Walk-Around Clipboard 5 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0223 (K-223): Survey Compliance Standard (K0223)

Facility: Chesapeake Shores Nursing Center Local Hotspot: #5 (2 nearby citations) Checklist: LSC
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are physical building zones and equipment covered by K0223 inspected and current in the maintenance log? [   ] Pass   [   ] Fix Fix note:
2. Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? [   ] Pass   [   ] Fix Fix note:
3. Were any open maintenance work orders resolved and dated by plant operations staff? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Where are weekly and monthly inspection records for K-223 stored? [   ] Answered Clearly   [   ] Coached
Q2. How do staff submit an urgent maintenance work order if equipment needs repair on shift? [   ] Answered Clearly   [   ] Coached
Q3. What safety step happens on your unit when the fire alarm activates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.