← Back to RadarPre-Survey County Walk-Around Packet (6 Separate 8.5" × 11" Letter Sheets)
Page 1 of 6 · Cover & Assignment Sheet 8.5" × 11" US Letter · 3-Hole-Punch Ready

Pre-Survey County Inspector Walk-Around Packet

Facility: Snow Hill Rehabilitation & Healthcare Center Location: Snow Hill, MD (Worcester County) Last Survey: 2026-05-08 (6 mos ago)
How to Use Hand 1 Sheet to Each Department Lead

State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Worcester (MD) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.

Today's 5 Sheets Top Tags Cited Nearby
Sheet Tag & Care Area Nearby Activity Hand Sheet To Result
Page 2 K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing 4 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 3 K0712 — Quarterly Fire Drills Conducted Across All Three Shifts 4 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 4 K0345 — Fire Alarm System Testing, Inspection, and Out-of-Service Fire Watch 4 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 5 K0211 — Means of Egress Clear and Unobstructed Corridors 4 local write-ups Maintenance Lead [   ] Pass   [   ] Fix
Page 6 F0880 — Infection Prevention and Control 4 local write-ups DON / Unit Nurse [   ] Pass   [   ] Fix
Administrator Sign-Off: ___________________ DON Sign-Off: ___________________ Date: __________
Page 2 of 6 · Walk-Around Clipboard 1 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0918 (K-918): Electrical Systems - Essential Electric System Maintenance and Generator Testing

Facility: Snow Hill Rehabilitation & Healthcare Center Local Hotspot: #1 (4 nearby citations) Checklist: LSC-K0918
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? [   ] Pass   [   ] Fix Fix note:
2. Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? [   ] Pass   [   ] Fix Fix note:
3. Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? [   ] Answered Clearly   [   ] Coached
Q2. Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? [   ] Answered Clearly   [   ] Coached
Q3. Within how many seconds must emergency generator power come on if utility power fails? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 3 of 6 · Walk-Around Clipboard 2 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0712 (K-712): Quarterly Fire Drills Conducted Across All Three Shifts

Facility: Snow Hill Rehabilitation & Healthcare Center Local Hotspot: #2 (4 nearby citations) Checklist: LSC-K0712
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Were unannounced fire drills completed at varied times at least once per quarter on Day, Evening, and Night shifts? [   ] Pass   [   ] Fix Fix note:
2. Do fire drill critique logs record alarm activation time, door closure, staff attendance, and corrective coaching? [   ] Pass   [   ] Fix Fix note:
3. Were silent night-shift drills between 9 PM and 6 AM followed by audible testing during daytime hours? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. What do the four letters in RACE stand for when responding to smoke or fire on your nursing unit? [   ] Answered Clearly   [   ] Coached
Q2. During a fire alarm, which residents near the fire origin are moved first beyond the smoke-barrier doors? [   ] Answered Clearly   [   ] Coached
Q3. Where are the last 12 quarterly shift fire drill logs filed when a Life Safety surveyor asks to see them? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 4 of 6 · Walk-Around Clipboard 3 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0345 (K-345): Fire Alarm System Testing, Inspection, and Out-of-Service Fire Watch

Facility: Snow Hill Rehabilitation & Healthcare Center Local Hotspot: #3 (4 nearby citations) Checklist: LSC-K0345
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are semi-annual smoke detector sensitivity checks and annual fire alarm vendor inspection reports complete in the binder? [   ] Pass   [   ] Fix Fix note:
2. Is the main fire alarm panel clear of unaddressed trouble signals during maintenance shift rounds? [   ] Pass   [   ] Fix Fix note:
3. Do staff know the written Fire Watch log procedure if the fire alarm system goes offline for more than 4 hours? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. If you hear a yellow trouble beep on the main fire alarm panel at the nurses' station, who do you call right away? [   ] Answered Clearly   [   ] Coached
Q2. Where is our facility Fire Watch clipboard kept if the alarm system is temporarily offline for maintenance? [   ] Answered Clearly   [   ] Coached
Q3. Where does the maintenance director file quarterly and annual fire alarm testing certificates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 5 of 6 · Walk-Around Clipboard 4 of 5 8.5" × 11" US Letter · Assign to Maintenance Director

K0211 (K-211): Means of Egress Clear and Unobstructed Corridors

Facility: Snow Hill Rehabilitation & Healthcare Center Local Hotspot: #4 (4 nearby citations) Checklist: LSC
Step 1 Walk the Unit & Check These 3 Items (5 Minutes)
1. Are physical building zones and equipment covered by K0211 inspected and current in the maintenance log? [   ] Pass   [   ] Fix Fix note:
2. Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? [   ] Pass   [   ] Fix Fix note:
3. Were any open maintenance work orders resolved and dated by plant operations staff? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. Where are weekly and monthly inspection records for K-211 stored? [   ] Answered Clearly   [   ] Coached
Q2. How do staff submit an urgent maintenance work order if equipment needs repair on shift? [   ] Answered Clearly   [   ] Coached
Q3. What safety step happens on your unit when the fire alarm activates? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.
Page 6 of 6 · Walk-Around Clipboard 5 of 5 8.5" × 11" US Letter · Assign to DON / Unit Nurse

F0880 (F-880): Infection Prevention and Control

Facility: Snow Hill Rehabilitation & Healthcare Center Local Hotspot: #5 (4 nearby citations) Checklist: CMS-20054
Step 1 Walk the Unit & Check These 4 Items (5 Minutes)
1. Do staff perform hand hygiene and change gloves between dirty and clean tasks during wound or incontinence care? [   ] Pass   [   ] Fix Fix note:
2. Is Enhanced Barrier Precautions (EBP) or Transmission-Based Precautions signage posted on the door with stocked PPE caddy? [   ] Pass   [   ] Fix Fix note:
3. Are glucometers and shared vital-sign equipment disinfected with EPA-registered wipes observing exact wet-contact time? [   ] Pass   [   ] Fix Fix note:
4. Is clean linen kept covered and separated from soiled utility bags in hallways? [   ] Pass   [   ] Fix Fix note:
Step 2 Ask 2 Staff on Shift These Quick Questions (2 Minutes)
Q1. What is the wet-contact kill time printed on our facility's disinfectant wipes before a shared glucometer can be reused? [   ] Answered Clearly   [   ] Coached
Q2. When caring for a resident on Enhanced Barrier Precautions with an indwelling catheter or wound, when must you wear gown and gloves? [   ] Answered Clearly   [   ] Coached
Q3. During peri-care or dressing changes, at what exact point must you remove dirty gloves and sanitize your hands? [   ] Answered Clearly   [   ] Coached
Checked By: _______________________ Unit / Wing: _______________ Date: ___________
Privacy Rule: Never write resident names or room numbers on walk-around sheets.