State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Worcester (MD) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 3 | K0712 — Quarterly Fire Drills Conducted Across All Three Shifts | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 4 | K0345 — Fire Alarm System Testing, Inspection, and Out-of-Service Fire Watch | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 5 | K0211 — Means of Egress Clear and Unobstructed Corridors | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | F0880 — Infection Prevention and Control | 4 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Were unannounced fire drills completed at varied times at least once per quarter on Day, Evening, and Night shifts? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Do fire drill critique logs record alarm activation time, door closure, staff attendance, and corrective coaching? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were silent night-shift drills between 9 PM and 6 AM followed by audible testing during daytime hours? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What do the four letters in RACE stand for when responding to smoke or fire on your nursing unit? | [ ] Answered Clearly [ ] Coached |
| Q2. | During a fire alarm, which residents near the fire origin are moved first beyond the smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where are the last 12 quarterly shift fire drill logs filed when a Life Safety surveyor asks to see them? | [ ] Answered Clearly [ ] Coached |
| 1. | Are semi-annual smoke detector sensitivity checks and annual fire alarm vendor inspection reports complete in the binder? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Is the main fire alarm panel clear of unaddressed trouble signals during maintenance shift rounds? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Do staff know the written Fire Watch log procedure if the fire alarm system goes offline for more than 4 hours? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | If you hear a yellow trouble beep on the main fire alarm panel at the nurses' station, who do you call right away? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is our facility Fire Watch clipboard kept if the alarm system is temporarily offline for maintenance? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where does the maintenance director file quarterly and annual fire alarm testing certificates? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0211 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-211 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Do staff perform hand hygiene and change gloves between dirty and clean tasks during wound or incontinence care? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Is Enhanced Barrier Precautions (EBP) or Transmission-Based Precautions signage posted on the door with stocked PPE caddy? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are glucometers and shared vital-sign equipment disinfected with EPA-registered wipes observing exact wet-contact time? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Is clean linen kept covered and separated from soiled utility bags in hallways? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the wet-contact kill time printed on our facility's disinfectant wipes before a shared glucometer can be reused? | [ ] Answered Clearly [ ] Coached |
| Q2. | When caring for a resident on Enhanced Barrier Precautions with an indwelling catheter or wound, when must you wear gown and gloves? | [ ] Answered Clearly [ ] Coached |
| Q3. | During peri-care or dressing changes, at what exact point must you remove dirty gloves and sanitize your hands? | [ ] Answered Clearly [ ] Coached |