State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Warren (KY) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | K0353 — Sprinkler System - Maintenance, Inspection, and 18-Inch Storage Clearance | 4 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 3 | F0689 — Free of Accident Hazards, Supervision, and Assistance Devices | 4 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 4 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 2 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 5 | K0361 — Survey Compliance Standard (K0361) | 2 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | K0351 — Survey Compliance Standard (K0351) | 2 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| 1. | Do staff maintain at least 18 inches of vertical safety clearance below sprinkler heads in dietary, linen, and supply closets? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are sprinkler heads in resident rooms and corridors clean and free of paint, lint, or hanging items during maintenance inspection? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are quarterly flow tests and annual sprinkler inspection logs current in the facility maintenance binder? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | How many inches of open safety space must staff keep below sprinkler heads on top shelves of storage closets? | [ ] Answered Clearly [ ] Coached |
| Q2. | Can staff ever hang privacy curtains, clothes, or wires from sprinkler piping in a resident room? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where does the maintenance director keep quarterly and annual sprinkler inspection records? | [ ] Answered Clearly [ ] Coached |
| 1. | Do transfer methods and mechanical lift sling sizes used by CNAs match the resident's active care plan and Kardex? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Were new fall-prevention interventions put in place immediately after the resident's most recent fall? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are call lights within reach, floor mats positioned as ordered, and bed heights set appropriately? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are smoking aprons, oxygen safety signs, and elopement wander-guards functioning and checked per shift? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Before transferring a resident with a mechanical lift, where do you check how many staff and which sling size are required? | [ ] Answered Clearly [ ] Coached |
| Q2. | When a resident has an unwitnessed fall, what immediate checks and care-plan updates happen before end of shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | Before walking out of a high-fall-risk resident's room, what three bedside items do you verify? | [ ] Answered Clearly [ ] Coached |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0361 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-361 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |
| 1. | Are physical building zones and equipment covered by K0351 inspected and current in the maintenance log? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are corridor doors, storage clearances, and life-safety test sheets free of open discrepancies? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were any open maintenance work orders resolved and dated by plant operations staff? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Where are weekly and monthly inspection records for K-351 stored? | [ ] Answered Clearly [ ] Coached |
| Q2. | How do staff submit an urgent maintenance work order if equipment needs repair on shift? | [ ] Answered Clearly [ ] Coached |
| Q3. | What safety step happens on your unit when the fire alarm activates? | [ ] Answered Clearly [ ] Coached |