State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Ellis (KS) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | K0353 — Sprinkler System - Maintenance, Inspection, and 18-Inch Storage Clearance | 3 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 3 | K0345 — Fire Alarm System Testing, Inspection, and Out-of-Service Fire Watch | 3 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 4 | K0321 — Hazardous Areas - Enclosure and Self-Closing Smoke Doors | 3 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 5 | F0757 — Drug Regimen Free from Unnecessary Medications and Missing Monitoring | 3 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 6 | F0756 — Monthly Drug Regimen Review and Timely Physician Follow-Up | 3 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| 1. | Do staff maintain at least 18 inches of vertical safety clearance below sprinkler heads in dietary, linen, and supply closets? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are sprinkler heads in resident rooms and corridors clean and free of paint, lint, or hanging items during maintenance inspection? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are quarterly flow tests and annual sprinkler inspection logs current in the facility maintenance binder? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | How many inches of open safety space must staff keep below sprinkler heads on top shelves of storage closets? | [ ] Answered Clearly [ ] Coached |
| Q2. | Can staff ever hang privacy curtains, clothes, or wires from sprinkler piping in a resident room? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where does the maintenance director keep quarterly and annual sprinkler inspection records? | [ ] Answered Clearly [ ] Coached |
| 1. | Are semi-annual smoke detector sensitivity checks and annual fire alarm vendor inspection reports complete in the binder? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Is the main fire alarm panel clear of unaddressed trouble signals during maintenance shift rounds? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Do staff know the written Fire Watch log procedure if the fire alarm system goes offline for more than 4 hours? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | If you hear a yellow trouble beep on the main fire alarm panel at the nurses' station, who do you call right away? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is our facility Fire Watch clipboard kept if the alarm system is temporarily offline for maintenance? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where does the maintenance director file quarterly and annual fire alarm testing certificates? | [ ] Answered Clearly [ ] Coached |
| 1. | Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order? | [ ] Answered Clearly [ ] Coached |
| Q3. | When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |
| 1. | Do high-risk resident medications (anticoagulants, insulin, diuretics, opioids) have active physician lab and vital-sign orders? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are duplicate PRN pain or bowel medication orders clarified on the MAR so nursing staff know exact dosing rules? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are antibiotic treatment stop dates and clinical indications entered clearly for every resident? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | If a resident has two PRN pain medication orders on the MAR, how do nursing staff verify which dose to administer? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where on the MAR does the nurse check blood-sugar or blood-pressure parameters before giving high-risk medication? | [ ] Answered Clearly [ ] Coached |
| Q3. | What physician review is needed before continuing an antibiotic order past its scheduled stop date? | [ ] Answered Clearly [ ] Coached |
| 1. | Did the consultant pharmacist complete a monthly medication regimen review for every resident in the facility? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Did the attending physician review pharmacist medication reports and sign orders or clinical rationale timely? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were urgent medication safety alerts reported to the Director of Nursing and physician within 24 hours? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | When the consultant pharmacist leaves a medication review note for the physician, where do nursing staff track it? | [ ] Answered Clearly [ ] Coached |
| Q2. | How fast must an urgent medication safety alert reach the Director of Nursing and attending physician? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who audits unsigned pharmacist medication review notes during weekly clinical meetings? | [ ] Answered Clearly [ ] Coached |