State surveyors inspect nursing homes on an unannounced 9-to-15 month cycle. Each sheet covers one of the 5 tags most frequently cited nearby in Kenai Peninsula (AK) so nursing, dietary, and maintenance leads can audit units, ask staff three hallway questions, and log fixes for monthly QAPI review.
| Sheet | Tag & Care Area | Nearby Activity | Hand Sheet To | Result |
|---|---|---|---|---|
| Page 2 | F0812 — Food Procurement, Store, Prepare, and Serve Sanitary | 2 local write-ups | Dietary Manager | [ ] Pass [ ] Fix |
| Page 3 | F0761 — Labeling and Storage of Drugs and Biologicals | 2 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 4 | F0657 — Care Plan Timing and Revision After Assessment or Change | 2 local write-ups | DON / Unit Nurse | [ ] Pass [ ] Fix |
| Page 5 | K0918 — Electrical Systems - Essential Electric System Maintenance and Generator Testing | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| Page 6 | K0712 — Quarterly Fire Drills Conducted Across All Three Shifts | 1 local write-ups | Maintenance Lead | [ ] Pass [ ] Fix |
| 1. | Are all opened dry goods, walk-in cooler items, and freezer items tightly sealed, labeled, and dated with use-by dates? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are dishmachine wash/rinse temperatures or three-compartment sanitizer test strips logged before every meal service? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are dietary staff wearing hair restraints, clean aprons, and changing gloves appropriately? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are food holding temperatures logged and kept >= 135 F for hot foods and <= 41 F for cold foods until served? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What is the required sanitizer concentration (ppm) for our three-compartment sink test strips, and when is it logged? | [ ] Answered Clearly [ ] Coached |
| Q2. | If you find an undated or expired item inside the nourishment fridge or walk-in cooler, what do you do immediately? | [ ] Answered Clearly [ ] Coached |
| Q3. | What minimum temperature must hot food maintain on the steam table before tray delivery starts? | [ ] Answered Clearly [ ] Coached |
| 1. | Are all medication carts and treatment carts locked whenever out of the nurse's direct line of sight? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are multi-dose vials (such as insulin and tuberculin) labeled with open date and 28-day expiration date? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are Schedule II controlled substances stored inside separately locked, permanently affixed compartments? | [ ] Pass [ ] Fix | Fix note: |
| 4. | Are discontinued, expired, or discharged residents' medications promptly removed to the locked pharmacy-return bin? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | If you step into a resident's room or walk down the hall, what must you do with your medication or treatment cart first? | [ ] Answered Clearly [ ] Coached |
| Q2. | Once you puncture a multi-dose insulin vial, what date goes on the label and when does it expire? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where do discontinued blister packs go at the end of a med pass, and where is that return bin kept? | [ ] Answered Clearly [ ] Coached |
| 1. | Was the resident care plan updated promptly by nursing staff after each fall, weight loss trigger, new wound, or hospital return? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are resident and family preferences documented from quarterly care-plan review meetings? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Do updated care-plan safety steps match active physician orders on the medication and treatment records? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | After a resident returns from the hospital with new physician orders, what care-plan review happens before next shift? | [ ] Answered Clearly [ ] Coached |
| Q2. | When a resident falls on night shift, how do day-shift nursing staff see the updated safety intervention? | [ ] Answered Clearly [ ] Coached |
| Q3. | Who leads quarterly care-plan review meetings and logs resident or family input? | [ ] Answered Clearly [ ] Coached |
| 1. | Are weekly generator visual inspections (fuel, battery electrolyte/specific gravity, coolant, oil) logged every single week? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Are monthly 30-minute dynamic load tests (>= 30% nameplate kW or exhaust temperature threshold) documented for all 12 months? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Are transfer switch time-delay seconds (< 10 seconds to restore emergency power) recorded on every monthly test sheet? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | Which color electrical outlets at the nurses' station and resident rooms stay powered by the emergency generator? | [ ] Answered Clearly [ ] Coached |
| Q2. | Where is the emergency generator inspection binder stored if a Life Safety surveyor asks to review the last 12 monthly load tests? | [ ] Answered Clearly [ ] Coached |
| Q3. | Within how many seconds must emergency generator power come on if utility power fails? | [ ] Answered Clearly [ ] Coached |
| 1. | Were unannounced fire drills completed at varied times at least once per quarter on Day, Evening, and Night shifts? | [ ] Pass [ ] Fix | Fix note: |
| 2. | Do fire drill critique logs record alarm activation time, door closure, staff attendance, and corrective coaching? | [ ] Pass [ ] Fix | Fix note: |
| 3. | Were silent night-shift drills between 9 PM and 6 AM followed by audible testing during daytime hours? | [ ] Pass [ ] Fix | Fix note: |
| Q1. | What do the four letters in RACE stand for when responding to smoke or fire on your nursing unit? | [ ] Answered Clearly [ ] Coached |
| Q2. | During a fire alarm, which residents near the fire origin are moved first beyond the smoke-barrier doors? | [ ] Answered Clearly [ ] Coached |
| Q3. | Where are the last 12 quarterly shift fire drill logs filed when a Life Safety surveyor asks to see them? | [ ] Answered Clearly [ ] Coached |