In Texas, state surveyors recorded 29 citations for K0916 (K-916: Gas, Vacuum, and Electrical Systems Deficiencies) across recent 2025-2026 skilled nursing facility inspections. Recent citations in Texas were most active in Dallas, El Paso, Tarrant counties. To clear an onsite revisit without repeat deficiencies, Maintenance Director or designee teams typically pair immediate resident or building remediation with signed staff shift huddles and weekly for 4 weeks audit logs reviewed by the monthly QAPI committee.

Active TX Counties: Dallas County (5) → El Paso County (4) → Tarrant County (3) → Denton County (2) → Wise County (1) →

What Surveyors Check Onsite

  • Are physical building zones cited under K0916 inspected on every shift and logged in the maintenance binder?
  • Have maintenance staff verified and documented immediate physical repair with dated work orders?
  • Are weekly audit logs signed by the Maintenance Director and reviewed at monthly QAPI meetings?

3-Question Hallway Spot-Quiz

Review with nurses & CNAs during your 5-minute shift huddle:

  1. If you spot an equipment or corridor safety issue related to K-916, how do you report an urgent maintenance order?
  2. Where are weekly Life Safety inspection logs kept when state surveyors arrive?
  3. What safety check happens on your unit before ending your shift?

Approved State Plan Examples for K0916

Providence Point Healthcare Residence (PA)
Spot-checks: weekly × 8 weeks ✓ Passed Re-Inspection

1. Generator Remote Annunciator panel was reconnected and operational on 7/15/2026. 2. Generator Remote Annunciator Panel will audited each week for 8 weeks to ensure proper functioning. 3.…

View Full Plan Text (07/06/2026)
K0916 Correction Date: 07/31/2026 1. Generator Remote Annunciator panel was reconnected and operational on 7/15/2026. 2. Generator Remote Annunciator Panel will audited each week for 8 weeks to ensure proper functioning. 3. Results of audits will be reported at quarterly QA meetings. 4. EVS Director will be responsible for this plan of correction.
Hempfield Manor (PA)
Spot-checks: weekly × 4 weeks ✓ Passed Re-Inspection

On March 10, 2026, the remote alarm annunciator for the emergency generator was displaying three blinking fault lights. The codes were identified due to the high level of fuel in the fuel…

View Full Plan Text (03/10/2026)
K0916 Correction Date: 04/14/2026 On March 10, 2026, the remote alarm annunciator for the emergency generator was displaying three blinking fault lights. The codes were identified due to the high level of fuel in the fuel tank. Generator was run to reduce fuel level. The blinking lights were no longer present. Maintenance Director was educated by Nursing home administrator on the blinking codes on the annunciator panel. Maintenance Director will perform audits weekly x 4 weeks, and monthly x 3 months to ensure panel is operating and functional. Audits will be reviewed during QAPI Quarterly.