SA SurveyAnchor
State Guides › Pennsylvania › K-919 (K0919)

Pennsylvania K-919 Plan of Correction Guide

K0919 · Gas, Vacuum, and Electrical Systems Deficiencies

Build K-919 Plan & Binder →
✓ 2025–26 PA Citations: 16
✓ Common Audit Schedule: weekly for 4 weeks
✓ Checklist Source: CMS Life Safety Code

In Pennsylvania, state surveyors recorded 16 citations for K0919 (K-919: Gas, Vacuum, and Electrical Systems Deficiencies) across recent 2025-2026 skilled nursing facility inspections. Recent citations in Pennsylvania were most active in Luzerne, Lackawanna, Westmoreland counties. To clear an onsite revisit without repeat deficiencies, Maintenance Director or designee teams typically pair immediate resident or building remediation with signed staff shift huddles and weekly for 4 weeks audit logs reviewed by the monthly QAPI committee.

Active PA Counties: Luzerne County (3) → Lackawanna County (3) → Westmoreland County (1) → Wayne County (1) → Washington County (1) →

What Surveyors Check Onsite

  • Are physical building zones cited under K0919 inspected on every shift and logged in the maintenance binder?
  • Have maintenance staff verified and documented immediate physical repair with dated work orders?
  • Are weekly audit logs signed by the Maintenance Director and reviewed at monthly QAPI meetings?

3-Question Hallway Spot-Quiz

Review with nurses & CNAs during your 5-minute shift huddle:

  1. If you spot an equipment or corridor safety issue related to K-919, how do you report an urgent maintenance order?
  2. Where are weekly Life Safety inspection logs kept when state surveyors arrive?
  3. What safety check happens on your unit before ending your shift?

Approved State Plan Examples for K0919

Embassy of Scranton (PA)
Spot-checks: weekly × 4 weeks ✓ Passed Re-Inspection

Any storage kept in the basement-level electrical room was relocated to ensure a clearance of 36 inches from electrical panels. The Maintenance Director/designee will audit the basement-level…

View Full Plan Text (05/26/2026)
K0919 Correction Date: 06/30/2026 Any storage kept in the basement-level electrical room was relocated to ensure a clearance of 36 inches from electrical panels. The Maintenance Director/designee will audit the basement-level electrical room weekly x 4, then monthly to ensure that a clearance of 36 inches from the electrical panels is maintained for any storage. These audits will be brought to the monthly QAPI committee meeting for further review and recommendations.
Pocopson Home (PA)
Spot-checks: weekly × 4 weeks ✓ Passed Re-Inspection

1. The junction box, located within the West Wing tunnel (closest to the fire alarm strobe) has been covered with a junction box cover plate. The Maintenance department staff will inspect all…

View Full Plan Text (04/01/2026)
K0919 Correction Date: 04/02/2026 1.The junction box, located within the West Wing tunnel (closest to the fire alarm strobe) has been covered with a junction box cover plate. The Maintenance department staff will inspect all electrical junction boxes for the correct installation of covers during their weekly maintenance rounds. Audit results will be reported to the Quality Improvement/Infection Control Committee Preparation and submission of this Plan of Correction is required by State and Federal law. This Plan of Correction does not constitute an admission for purposes of general liability, professional malpractice or any other court proceeding.
Westmoreland Manor (PA)
Spot-checks: weekly × 4 weeks ✓ Passed Re-Inspection

Preparation and/or execution of this plan of correction does not constitute admission or agreement by the provider of the truth of the facts alleged or conclusions set forth in the statement…

View Full Plan Text (05/01/2025)
K0919 Correction Date: 05/14/2025 Preparation and/or execution of this plan of correction does not constitute admission or agreement by the provider of the truth of the facts alleged or conclusions set forth in the statement of deficiencies. The plan of correction is prepared and/or executed solely because it is required by the provisions of federal and state law. Maintenance removed the wheelchairs in the second-floor b-wing storage room that were obstructing the electrical panels on 5/1/2025. The Director of Maintenance/designee will conduct random weekly audits throughout the facility two times per week for two weeks then weekly for two weeks to ensure there are no electrical panels obstructed by wheelchairs. The results of these audits will be brought to the Quality Assurance and Performance Improvement Committee for further analysis and corrective actions.
Customize & Print 4-Sheet Revisit Binder →