✓ 2025–26 OH Citations: 145
✓ Common Audit Schedule: weekly for 4 weeks
✓ Checklist Source: LSC-K0321

In Ohio, state surveyors recorded 145 citations for K0321 (K-321: Hazardous Areas - Enclosure and Self-Closing Smoke Doors) across recent 2025-2026 skilled nursing facility inspections. Recent citations in Ohio were most active in Cuyahoga, Franklin, Summit counties. To clear an onsite revisit without repeat deficiencies, Maintenance Director or designee teams typically pair immediate resident or building remediation with signed staff shift huddles and weekly for 4 weeks audit logs reviewed by the monthly QAPI committee.

Active OH Counties: Cuyahoga County (21) → Franklin County (11) → Summit County (8) → Mahoning County (8) → Lorain County (8) →

What Surveyors Check Onsite

  • Do all soiled utility, laundry, storage (>50 sq ft), and mechanical room doors self-close and positive-latch completely?
  • Are wooden wedges, kick-down stops, or propped linen hampers completely absent from fire and smoke doors?
  • Are penetrations around pipes and data cables in smoke/fire walls sealed with listed firestop material?

3-Question Hallway Spot-Quiz

Review with nurses & CNAs during your 5-minute shift huddle:

  1. Why can staff never use a wedge or linen cart to prop open a soiled utility or storage room door, even for two minutes?
  2. If you notice a hallway or storage door failing to latch shut on its own, how do you submit an urgent maintenance work order?
  3. When the fire alarm sounds, what should happen automatically to corridor smoke-barrier doors?

Approved State Plan Examples for K0321

Margaret E. Moul Home (PA)
Spot-checks: monthly × 3 months ✓ Passed Re-Inspection

1. Self-closures have been ordered by Susquehanna Door for all 7 cited hazardous area doors. As soon as the closures are in stock, they will be installed. 2. All facility hazardous area doors…

View Full Plan Text (08/24/2026)
K0321 Correction Date: 09/30/2026 1. Self-closures have been ordered by Susquehanna Door for all 7 cited hazardous area doors. As soon as the closures are in stock, they will be installed. 2. All facility hazardous area doors will be inspected to ensure proper functioning self-closures are in place and latching properly. 3. Director of Environmental Services or designee will audit hazardous area doors for proper self-closure monthly for 3 months, and then quarterly for 3 quarters. Findings will be reported to the Quality Assessment and Assurance Committee for recommendations and need for further audits.
Concordia at Rp Home (PA)
Spot-checks: weekly × 4 weeks ✓ Passed Re-Inspection

1) Clean Linen Door in Laundry room was repaired by maintenance on day of discovery. Workorder on file with NHA. 2) Doorknob replaced to kitchen storage room on day of discovery. Workorder on…

View Full Plan Text (08/17/2026)
K0321 Correction Date: 10/01/2026 1) Clean Linen Door in Laundry room was repaired by maintenance on day of discovery. Workorder on file with NHA. 2) Doorknob replaced to kitchen storage room on day of discovery. Workorder on file with NHA. 3) Items removed upon discovery. Dining Service Staff re-educated to requirement. Proof of education on file with NHA. 4) Prop removed from door at mechanical room. Staff re-educated to not prop doors open. Signature sheets on file with NHA of proof of education. 5) QAPI notified of citation and repairs.