Minnesota K-311 Plan of Correction Guide

K0311 · Smoke Deficiencies

Build K-311 Plan & Binder →
✓ 2025–26 MN Citations: 16
✓ Common Audit Schedule: weekly for 4 weeks
✓ Checklist Source: CMS Life Safety Code

In Minnesota, state surveyors recorded 16 citations for K0311 (K-311: Smoke Deficiencies) across recent 2025-2026 skilled nursing facility inspections. Recent citations in Minnesota were most active in Washington, Ramsey, Hennepin counties. To clear an onsite revisit without repeat deficiencies, Maintenance Director or designee teams typically pair immediate resident or building remediation with signed staff shift huddles and weekly for 4 weeks audit logs reviewed by the monthly QAPI committee.

Active MN Counties: Washington County (4) → Ramsey County (4) → Hennepin County (4) → St. Louis County (2) → Dakota County (1) →

What Surveyors Check Onsite

  • Are physical building zones cited under K0311 inspected on every shift and logged in the maintenance binder?
  • Have maintenance staff verified and documented immediate physical repair with dated work orders?
  • Are weekly audit logs signed by the Maintenance Director and reviewed at monthly QAPI meetings?

3-Question Hallway Spot-Quiz

Review with nurses & CNAs during your 5-minute shift huddle:

  1. If you spot an equipment or corridor safety issue related to K-311, how do you report an urgent maintenance order?
  2. Where are weekly Life Safety inspection logs kept when state surveyors arrive?
  3. What safety check happens on your unit before ending your shift?

Approved State Plan Examples for K0311

Misericordia Nursing & Rehabilitation Center (PA)
Spot-checks: monthly × 4 weeks ✓ Passed Re-Inspection

1. The facility will maintain vertical openings between floors with construction and have a fire resistance of at least 2 hours. 2. The facility will repair the gap at the at the top of the…

View Full Plan Text (07/13/2026)
K0311 Correction Date: 08/03/2026 1. The facility will maintain vertical openings between floors with construction and have a fire resistance of at least 2 hours. 2. The facility will repair the gap at the at the top of the old linen chute wall located on the first-floor Soiled Utility Room, near resident room with a 2-hour rated fire stop. 3. Vertical openings will be checked monthly by maintenance staff for penetrations. If any penetrations are found, they will be sealed to maintain the proper rating. 4. Monthly inspection will be done to include findings and any follow-up action. Findings will be presented quarterly to QA Committee for further review and evaluation.
Holy Family Manor (PA)
Spot-checks: weekly × 4 weeks ✓ Passed Re-Inspection

1. Holy Family Manor is working with architects and engineers to develop a viable structural solution to achieve the required fire resistive integrity of the smoke compartment. In accordance…

View Full Plan Text (06/08/2026)
K0311 Correction Date: 07/31/2026 1. Holy Family Manor is working with architects and engineers to develop a viable structural solution to achieve the required fire resistive integrity of the smoke compartment. In accordance with TLW already in place, the attic space would become an interstitial space of the 3rd floor and bring the building back to construction type II (222). Holy Family Manor will bring these plans to the Department of Health Plan Review prior to initiation of work. Facility requests continuation of the existing F.S.E.S. on file. The third-floor attic hatch door was immediately closed by the Maintenance Department. 2. The Maintenance Director/Designee will conduct random audits 2 times weekly to ensure all vertical openings are closed and hatch door secured to the frames. Findings will be reported during our QAPI meeting.